Brands

Coleman furnace filter sizes

3 Coleman furnace models, 3 model families.

Pick the start of your model number, or search below.

TM9TTM9XYP9C

How to read a Coleman model number

York, Coleman and Luxaire are Johnson Controls brands that share model numbers, and the Bosch and older Nordyne mobile-home furnaces are covered here too. In the York-group tables, the cabinet letter plus the blower size digits pick the filter row.

York group: older T- and Y-prefix families

Brands: York, Coleman, Luxaire, Fraser-Johnston, Champion (T-prefix models are shared across JCI brands; Y=York-only, C=Coleman, L=Luxaire for YP9C/CP9C/LP9C).

Families covered: TM9V, TM8V/TMLV, TM9E, TM9Y, TM9X, TM9T, TM9M, TM8X/TMLX, TM8E/TMLE, TM8T/TMLT, TM8Y, TG8S/TGLS, TG9S, TP9C, YP9C, TL9E.

Example: TM9V080C16MP12C

CharactersWhat they mean
1-4family (T=tri-brand/York, M or G = series, 8/9 = 80% / 90%+ AFUE, L in 3rd position = low-NOx 80% version e.g. TMLX, TGLS; last letter = generation/motor type e.g. V variable speed, E standard ECM, X, Y, T, M modulating, C (P9C) modulating)
5-7input in thousands of Btu/h (040 = 40,000; 080 = 80,000)
8cabinet letter: A = 14.5 in, B = 17.5 in, C = 21 in, D = 24.5 in wide
9-10nominal blower CFM in hundreds (08 = 800, 10 = 1000, 12 = 1200, 16 = 1600, 20 = 2000, 22 = 2200)
11-12MP = multi-position
Restrevision digits / letters (11, 12, 13, C), vary

How it connects to the filter: Filter tables are keyed by nominal CFM + cabinet letter, so characters 8-10 select the row.

Where this comes from: York TM9V Technical Guide 5425616-YTG-E-0122, page 2 (Cabinet and duct dimensions table: TM9V080C16MP12C | 1600 | C | 21); York TG8S Technical Guide 363657-YTG-H-0616, page 2 (TG(8,L)S... lists TG8S and TGLS; TG(8,L)S080C22MP11 | 2200 | C | 21); York TM9X/TG8S/TM8X installation manuals (theacoutlet copies), page 9 (Table 3 Cabinet and Duct Dimensions: A=14 1/2, B=17 1/2, C=21, D=24 1/2).

Known exceptions:

Related families from the same maker group

These share parts of the numbering system with Coleman, so they can help with an older or rebadged label.

York Y-series (2024 and later)

Brands: York.

Families covered: Y81E, Y82E, Y82V, Y91E, Y92E, Y92V.

Example: Y81E080C16SMPS1

CharactersWhat they mean
1Y = York
2-381/82 = 80% non-condensing (single / two stage), 91/92 = 95-97% condensing (single / two stage)
4E = standard ECM blower, V = variable-speed ECM
5-7input in thousands of Btu/h
8cabinet letter A/B/C/D (same widths as legacy)
9-10nominal CFM in hundreds
11S = standard NOx, L = low NOx
12-13MP = multi-position
14-15revision (S1, C1)

Where this comes from: York Y81E Technical Guide 6368917-YTG-B-1024, page 7 (Y81E040A12S(L)MPS1 ... A ... 14 1/2); York Y91E Technical Guide 6414251-YTG-A-0624, page 7 (Y91E026A08SMPS1 A 14.5).

Not fully confirmed: Stage/motor meaning of digits 2-4 inferred from document titles (Y81E 'Single-Stage Standard ECM', Y82V 'Two-Stage Variable Speed ECM'); not from a printed nomenclature chart.

Bosch BGS80 and BGH96

Example: BGH96M080C4B

CharactersWhat they mean
1-3BGS = Bosch gas single-stage 80%, BGH = Bosch gas high-efficiency
4-5AFUE class (80, 96)
6M = multipoise
7-9input in thousands of Btu/h
10cabinet letter: A 14.5, B 17.5, C 21, D 24.5 in (verified against submittal dimension tables)
11nominal cooling tons of blower (3,4,5), inferred, not printed
12revision (A, B, C)

How it connects to the filter: Bosch filter tables are keyed by cabinet width only.

Where this comes from: Bosch BGS80 Engineering Submittal Sheet 09.2018, page 4; Bosch BGH96 Engineering Submittal Sheet 03.2024, page 4.

Nordyne M7RL (manufactured housing)

Example: M7RL 060A BWT

CharactersWhat they mean
M7manufactured-housing 95% downflow series
RLsingle stage (TL = two stage M7TL)
045/060/072input in thousands of Btu/h
Aper spec sheet; not decoded in doc
AW/BWcabinet A or B, front (door) return
T suffixtop return (AWT/BWT)

Where this comes from: Nordyne M7RL Technical Specifications 718D, page 1 (Shipping Weights: M7RL 045A AW* ... *May include suffix - T); Nordyne M7RL Installation Instructions 709404D, page 11 (Model numbers ending in AWT & BWT are factory configured for the return air to enter the top).

Not fully confirmed: A/B as cabinet is inferred from 'M7RL B Cabinet Shown'; widths not stated.

Nordyne MG2S (manufactured housing)

Example: MG2SB045F2ABM1

CharactersWhat they mean
Mmanufactured housing
Ggas furnace
2two stage
Sefficiency 96.0% (R = 95.0%)
Bcabinet fits 18in coil / cabinet option
045/060/072input in thousands of Btu/h
F/TF = front return downflow, T = top return downflow
A115V 1ph
1revision

Where this comes from: Nordyne MG2S Technical Specifications 257F-0725, page 7 (MODEL IDENTIFICATION CODE chart).

Not fully confirmed: The chart's column order is hard to read in text extraction; F/T, input and S/R are certain, other positions are best-effort.